Drilled Pier Frost Heave | Eng-Tips
Feb 11, 2025 · Hello, I am currently designing concrete drilled piers, and per the geotech report, the recommendations incur a 1600 psf design stress for potential frost heave. The recommendations …
Can foundation weight allow avoidance of frost depth? | Eng-Tips
Mar 3, 2011 · A contractor is suggesting the use of 1ft deep, very wide concrete slab to support heavy rotating equipment. The local jurisdiction has a required frost depth 42in. Can a very heavy …
Frost depth for turndown slab | Eng-Tips
Jul 30, 2010 · I have virtually an unheated metal shack. It will sit on a slab on grade with a turndown. Is is necessary for the turndown to bear below the frost depth? In my mind, only unheated bearing …
Can flow fill (CLSM) be used as a fill material to meet frost ...
Oct 23, 2015 · I have an equipment foundation that needs to be frost protected. In this case, the frost depth is 48". In section 4.2 of ASCE 32 it states, "Foundations placed on a layer of well-drained, …
Actual frost depths | Eng-Tips
Oct 13, 2003 · I am trying to find some type of map which show the actual depth of frost for different areas, maybe a break down by county (USA). I am from Mass, the state building code states 4'-0" …
Lateral Pressure from Frost? | Eng-Tips
Feb 29, 2004 · Is there a prescribed method for designing against lateral frost pressure? How does the magnitude of pressure exerted by frost compare with hydrostatic pressure? I am considering various …
Frost Protection for Interior Footings | Eng-Tips
Nov 18, 2024 · If the building is heated there is no need to frost protect interior footings. On the other hand, if the structure is an unheated warehouse, then they should be protected just as exterior …
Cantilever Retaining Wall Frost Depth | Eng-Tips
Mar 6, 2019 · Frost penetrates deeper when the wall is not adjacent to a heated space, so frost depth outside the wall of a heated building will be shallower than a retaining wall in an open field.
Frost line consideration for walkout basement | Eng-Tips
Oct 21, 2024 · Hello, What is your opinion regarding the bottom of new foundation for the basement walkout stair? Creating a walkout for the basement will affect the frost line. Should I start counting …
Frost protection of foundations | Eng-Tips
Aug 10, 2015 · Frost depth in busy roads, normal winter 5-7 feet, residential roads 46 feet in the yards adjacent to both roads, 2-3 feet. And yes when I was there we installed and repaired sewer pipes all …